Sarigul Laboratories · Research use only

Synthetic human
urine solutions.

Defined composition. Flexible formulations.

Reliable synthetic urine matrices for research, testing, and product development.

Sarigul Laboratories UR001 bottle labeled Research-Grade Synthetic Human Urine
Product illustration · Packaging and color may vary
Chemically defined matricesSynthetic, non-biological originReady-to-use liquid
Products

Choose your synthetic urine.

Four core products.
Preserved, colored and custom formulation options.

UR001

Research-Grade Synthetic Human Urine

Human-data-informed synthetic urine developed to reflect selected biochemical characteristics of human urine. Designed for laboratory research, analytical method development, and product evaluation.

Configuration
UR001 — Standard
Request a quote ↗
UR002

Catheter Testing Simulated Urine

Simulated urine based on the reference formulation specified in ISO 20696:2018, for laboratory testing of urethral catheter materials and components.

Configuration
UR002 — Standard
Request a quote ↗
UR003

Absorbency Test Solution

Standardized 9 g/L sodium chloride solution for absorption capacity testing of urine-absorbing products, based on ISO 11948-1:1996 test-liquid specifications.

Configuration
UR003 — Standard
Request a quote ↗
UR004

Artificial Urine for Corrosion Testing

Artificial urine reference electrolytes based on ASTM F2129 formulations, developed for electrochemical corrosion testing of medical device materials intended for urinary tract applications.

Configuration
UR004 — Standard
Request a quote ↗
UR005

Custom Synthetic Urine Formulation

Tailor-made synthetic urine formulations developed to meet specific research, analytical testing, and product development requirements.

Formulation
UR005 — Custom formulation
Discuss formulation ↗

Bottle sizes: 100 mL · 250 mL · 500 mL · 1 L

Specifications and suitability are confirmed for your selected formulation.

UR001 composition & product specifications

Composition

Organic constituents

  • Urea
  • Creatinine
  • Uric acid
  • Citrate
  • Oxalate

Inorganic constituents

  • Sodium
  • Potassium
  • Calcium
  • Magnesium
  • Ammonium
  • Chloride
  • Sulfate
  • Phosphate

Product specifications

Product specifications
ParameterDescription
Product CodeUR001
Product TypeResearch-Grade Synthetic Human Urine
CompositionChemically defined
pHContact us for current specifications
AppearanceClear liquid
ColorColorless or optional color
PreservationPreservative-free or preserved
Sample OriginSynthetic, non-biological
FormatReady-to-use liquid
Product options

Preservation, color & packaging.

01 / PRESERVATION

Preservative-Free

Without added antimicrobial preservatives, for applications requiring reduced chemical interference.

Preserved

A selected antimicrobial preservation system for applications requiring additional protection against microbial contamination.

Preservation availability and storage conditions depend on formulation-specific compatibility and stability testing.

02 / COLOR

Visual simulation

ColorlessLight YellowYellowAmber

Custom color upon request.

Colorants may affect certain analytical methods.

Custom formulation

Custom synthetic urine formulations.

Adjust chemical composition, target pH and other properties to meet your research requirements.

Modify an existing formulation or request a custom-designed matrix.

Discuss a custom formulation ↗

[email protected]

Available chemical constituents
  • Urea
  • Creatinine
  • Uric acid
  • Sodium
  • Potassium
  • Calcium
  • Magnesium
  • Chloride
  • Ammonium
  • Phosphate
  • Sulfate
  • Citrate
  • Oxalate
  • Glucose
  • Albumin
  • Hippurate
  • Bicarbonate
  • Additional components upon request
Customizable properties
  • Target pH
  • Component concentration
  • Color and appearance
  • Preservative selection
  • Packaging volume
  • Application-specific requirements

Custom formulations are reviewed for chemical compatibility, solubility, and intended use before acceptance.

Research applications

For your laboratory workflow.

Analytical method developmentFTIR & Raman spectroscopyBiomedical researchBiosensor evaluationIn vitro & device testing

Suitability is assessed for each application; listed uses do not imply validated performance.

Technical documentation

Technical documentation.

Contact us for current specifications, handling information and documentation for your selected formulation.

Request technical documentation ↗

Discuss your documentation needs

  • Technical Data Sheet (TDS)
  • Safety Data Sheet (SDS)
  • Certificate of Analysis (CoA)
  • Composition and compatibility information

Document availability and scope are confirmed for the formulation and lot being quoted.

Research Use Only (RUO)

Products are intended for laboratory research, development, and in vitro testing. Not intended for clinical diagnosis, treatment, human administration, or substitution for authentic human specimens.

Let’s talk about your project

Request a quote.

Tell us your selected product, quantity and intended application. For UR005, include your custom formulation requirements.

You can also email us directly:

Orders are arranged by quote. Pricing, product details and delivery timing are confirmed before purchase.

Additional requirements Optional
Color
Please advise

We use your details to respond to your inquiry. Please do not include patient or sensitive personal information.

A few useful details

Before you order.

How do I place an order?

Request a quote with your application and quantity. Product details, pricing and delivery timing will be discussed before an order is confirmed.

Can I request specific technical requirements?

Yes. Include your desired formulation criteria, pH, packaging and other requirements in your inquiry. Our team will discuss feasibility and availability.

Where can I find storage and shelf-life information?

Contact us for information specific to the product being quoted. Follow the supplied storage and handling instructions.

Is this intended for clinical use?

No. Products are for laboratory research, development and in vitro testing. They are not intended for clinical diagnosis, treatment, human administration, or substitution for authentic human specimens.